PERFORMANCE OF A HYBRID SYNCHRONOUS RELUCTANCE MACHINE CAPABLE OF ULTRA – HIGH OUTPUT POWER

ABSTRACT
 
 
The performance of a hybrid synchronous reluctance machine capable of ultra-high Xd/Xq ratio and output power has been studied. A d-q model (voltage and flux linkage) of the hybrid synchronous reluctance machine has been idealized and developed. Also, the impedance and current loci from the steady state analysis of the synchronous reluctance machine was obtained. The effect of capacitor loading in the auxiliary windings was investigated. The power factor and torque developed in the hybrid synchronous reluctance machine was compared with conventional synchronous reluctance machine. This hybridized synchronous reluctance machine improved the major constraints of conventional synchronous reluctance machine: – low output power and poor power factor due to low ratio of direct to quadrature axis reactance (Xd/Xq). To achieve this, two elemental synchronous reluctance machines were conceived. Both were integrally wound with two identical windings in the stator. The rotor of one of the synchronous reluctance machine component is round while the other has salient pole. Both machine halves were mechanically coupled together. One set of the windings of both machines were connected in series and fed from the ac mains while the other set was also connected in series (but transposed between the two sections of the machine) and then connected to a balanced three-phase variable capacitance load. The Voltage and flux linkage equations were written in abc reference frame for the hybrid machine and then transformed to dqo variable. The steady state and dynamic equivalent circuits of the hybrid machine were developed using classical means. The impedance and current loci for the developed model were generated using Matlab m-files for various values of load angles and capacitance as parameters. The power factor and torque developed in the hybrid machine were compared with those of the conventional synchronous reluctance machine. It is shown that the capacitance loading of the auxiliary windings makes the overall Xd/Xq ratio of the hybrid machine to be a variable that can theoretically attain values between zero and infinity. This translates to ultra-high power output and unity power factor. Also, it is shown that the hybrid synchronous reluctance machine has a power factor control, a feat which is not feasible in conventional synchronous reluctance machines.

TABLE OF CONTENTS

Abstract

CHAPTER ONE

1.0    Introduction

1.1   Background of Study

1.2   Statement of Problems

1.3   Research Objectives

1.4   Research Question

1.5   Research Hypothesis   

1.6   Scope of Study

1.7   Significance of study

1.8   Limitation of study

1.9   Definition of terms

CHAPTER TWO

2.0   Literature Review

CHAPTER THREE

3.0   Research methodology

3.1   Research Design

3.2   Population of study

3.3   Sampling Design and Procedure

3.4   Data Collection Instrument

3.5   Administration of Data Collection Instrument

3.6   Methods of data analysis

CHAPTER FOUR

4.0   Data Presentation and Analysis

4.1   Data Presentation  

4.2   Test of Hypothesis 

CHAPTER FIVE

5.0   Summary, Conclusion and Recommendation

5.1   Summary

5.2   Conclusion

5.3    Recommendation

References

Questionnaire

You May Also Like