During the electrolysis of copper (II) tetraoxosulphate (VI) solution, an ammeter shows a steady reading of 1A for 30minutes while 6.6 x (10^{-4})kg of copper is liberated. Calculate the error in the ammeter The electrochemical equivalent of copper is 3.30 x (10^{-7}kgC{-1})
  • A.
    0.001A
  • B.
    0.011A
  • C.
    0.111A
  • D.
    1A
  • E.
    1.1A
Correct Answer: Option C
Explanation

m=zIt, (I=frac{m}{zt}= frac{6.6times10^{-4}}{3.3 times10^{-7}times 1800}=1.1111\ )error=1.1111-1.0=0.111A.